This paper presents a regenerative braking energy management strategy for an automated people mover (APM) equipped with a battery–supercapacitor hybrid energy storage system (HESS). The strategy was evaluated using measured distance, speed, and gradient data from the 4.8 km APM test route at KMUTNB, Prachinburi Campus. Two operating cycles, covering 9.06 km and four passenger stations, were analyzed under two cases: supercapacitor operation without a discharge power factor and operation with an optimized discharge power factor. Sequential Quadratic Programming (SQP), a Genetic Algorithm (GA), and Hippopotamus Optimization (HO) were used to determine the maximum supercapacitor power, supercapacitor capacity, and discharge power factor while reducing battery peak power and unrecovered regenerative braking energy. For the present case study, HO achieved the best performance, yielding an optimal supercapacitor power of 53.8887 kW, capacity of 1.9984 kWh, and discharge power factor of 0.1158. Compared with the baseline case, the optimized HESS reduced battery peak power by 87.86%, unrecovered regenerative braking energy by 99.70%, and battery energy consumption by 90.14%. These results demonstrate that the proposed HESS strategy effectively enhances regenerative energy utilization and reduces battery power and energy demands in APM operation.