Deep beams strengthened with glass fiber-reinforced polymer (GFRP) bars are gaining popularity in harsh environments because they don't rust. However, we still don't fully understand how they behave when they are sheared, especially how the shear span-to-effective depth ratio (av/d) affects them. This study empirically examines the shear response of GFRP-reinforced concrete deep beams with differing av/d ratios. Six deep beams underwent testing under monotonic four-point loading with av/d ratios of 1.0, 1.5, and 2.0, utilizing both closed and spiral GFRP stirrups with varying spacing. The findings demonstrate that reducing the av/d ratio markedly improves shear capacity and stiffness, while also transforming the predominant failure mechanism from diagonal tension to shear compression. Beams with spiral GFRP stirrups had better shear strength and crack control than beams with closed stirrups. Reducing the space between the stirrups also improved shear performance. When compared to current design guidelines, ACI 318-19 makes predictions about the shear strength of GFRP-reinforced concrete deep beams that are either too low or just right. The results furnish empirical evidence to advocate for enhanced shear design and modeling of GFRP-reinforced concrete deep beams.